Awaab's Law Phase 2 Starts on 30 November: What Contractors Need to Be Ready For

On 30 November, the second phase of Awaab's Law comes into force. For social landlords it is a compliance deadline. For the contractors and subcontractors doing the work, it is an operational one.

What changes

Phase 1 started in October 2025 and covered damp and mould and emergency hazards. From 30 November 2026 it also covers hazards that present a significant risk of harm, including excess cold, excess heat, falls, structural collapse, fire and explosions, electrical hazards and domestic hygiene.

The timescales

Emergency hazards must be investigated and made safe within 24 hours of the landlord becoming aware.

For significant hazards, the landlord must investigate within 10 working days, and complete safety work within 5 working days of the investigation concluding. The tenant must receive a written summary within 3 working days of the investigation concluding.

Permanent repairs must start, or steps must be taken to start them, within 5 working days of the investigation. If that is not reasonably practicable, work should begin as soon as it reasonably can and within 12 weeks. If safety work cannot be completed in time, the landlord may have to provide alternative accommodation at its own expense.

What it means for contractors

These deadlines run from the moment the landlord becomes aware of a hazard, and government guidance says that can include when a contractor becomes aware, depending on whether the contractor is acting as the landlord's agent. That puts a real emphasis on clear instructions and quick reporting of anything found on site.

Investigations must be carried out by someone the landlord reasonably considers competent. For electrical hazards, for example, that means a qualified electrician. Landlords also need good records of access attempts, because tenants must be given at least 24 hours' written notice and a reasonable appointment time.

The practical result is more demand for responsive repairs, electrical, fire safety, roofing, joinery and general building trades, with less tolerance for slow mobilisation. Phase 3 is also expected to extend the rules to the remaining hazards, although no date has been set.

The capacity question

A shorter clock means main contractors need accredited, insured and competent subcontractors who can respond quickly. Tier 1 clients expect Constructionline, CHAS or SafeContractor, appropriate insurance and a proven track record in occupied homes.

How Empower Consulting can help

Empower Consulting connects main contractors with pre-vetted, accredited subcontractors across all trades. We cover the whole of England, and there is no cost to the main contractor. If you are planning for Phase 2 and need dependable capacity, get in touch through our website.

Ready to mobilise anywhere in England, at no cost to the main contractor.

www.empowerconsulting.co.uk

© Empower Consulting Ltd 2026

Need support on your next programme?

Who we support

Services

Quick Links

Contact

Tel +44 07803 566 827

Registered Office

UK Social Housing & Construction Delivery Support

Empower Consulting Ltd

Registered in England & Wales Co No. 16050321

70 Church Road, London E10 7BH